Assessment of mean glandular dose (MGD) from mammographic examinations at Ubon Ratchathani Cancer Hospital
Keywords:
Mammography, Mean glandular dose, Breast cancer, Digital breast tomosynthesis, Full-field digital mammographyAbstract
Screening for breast cancer with mammography plays a critical role in reducing mortality among women. However, exposure to X-ray radiation during the examination can affect breast tissue, making it essential to evaluate the Mean Glandular Dose (MGD) in order to confirm safety and compare it against national reference levels. This study was a descriptive cross-sectional design. Its objectives were to assess and compare the MGD delivered by two-dimensional full-field digital mammography (FFDM) and three-dimensional digital breast tomosynthesis (DBT) using a Hologic Selenia Dimensions system equipped with an anti-scatter grid. Image‐acquisition parameters were collected from 100 female patients aged 40–60 years, yielding a total of 400 exposures. MGD was calculated according to internationally recognized protocols. The results showed that the MGD for FFDM ranged from 1.72 to 1.78 mGy, while for DBT it ranged from 1.75 to 1.82 mGy. Although DBT exhibited a slightly higher MGD, both modalities remained well below the 2023 National Diagnostic Reference Level (DRL) of 2.5 mGy. Moreover, DBT provided superior image quality and reduced the need for repeat examinations. In conclusion, DBT is both safe and effective for breast-cancer screening; nevertheless, further longitudinal studies are recommended to refine and optimize examination protocols.
Downloads
References
International Atomic Energy Agency. Dosimetry in diagnostic radiology: an international code of practice [Internet]. [cited 2024 February 21]. Available from: https://www.iaea.org/publications/7638/dosimetry-in-diagnostic-radiology-an-international-code-of-practice.
งานทะเบียนโรงพยาบาลมะเร็งอุบลราชธานี กรมการแพทย์ กระทรวงสาธารณสุข. สถิติโรคมะเร็ง โรงพยาบาลมะเร็งอุบลราชธานี ปี พ.ศ. 2565 [อินเตอร์เน็ต]. [สืบค้นเมื่อ 2 มีนาคม 2568]. แหล่งข้อมูล: https://anyflip.com/dmxje/xlnh/
กรมวิทยาศาสตร์การแพทย์ กระทรวงสาธารณสุข.
ค่าปริมาณรังสีอ้างอิงในการถ่ายภาพรังสีวินิจฉัยทางการแพทย์ของประเทศไทย 2564. พิมพ์ครั้งที่ 1.นนทบุรี: สำนักพิมพ์ บริษัท บียอนด์ พับลิสซิ่งจำกัด; 2564.
กรมวิทยาศาสตร์การแพทย์ กระทรวงสาธารณสุข. มาตรฐานคุณภาพเครื่องเอกซเรย์วินิจฉัย. พิมพ์ครั้งที่ 1. นนทบุรี: บริษัท บียอนด์ พับสิสชิ่ง จำกัด; 2566.
Vano E, Miller DL, Martin CJ, Rehani MM, Kang K, Rosenstein M, et al. ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Annals of the ICRP. 2017; 46(1):1-144.
Sechopoulos I, Dance DR, Boone JM, Bosmans HT, Caballo M, Diaz O, et al. Joint AAPM Task Group 282/EFOMP Working Group Report: Breast dosimetry for standard and contrast-enhanced mammography and breast tomosynthesis. Medical Physics 2023; 50(12), 712-39.
International Commission on Radiological Protection. ICRP Publication 102: Radiological protection in cardiology. Ann ICRP 2005;35(2):1–80.
European Commission. European Guidelines on Quality Assurance in Breast Cancer Screening and Diagnosis [Internet]. [cited 2024 February 25]. Available from: https://ec.europa.eu/health/ph_projects/2002/cancer/fp_cancer_2002_ext_guid_01.pdf.
Skaane P, Bandos AI, Gullien R, Eben EB, Ekseth U, Haakenaasen U, et al. Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. Radiology 2013;267(1):47–56.
อนงค์ สิงกาวงไซย์. การวัดปริมาณรังสีเฉลี่ยที่ต่อมน้ำนมจากการเอกซเรย์เต้านมในโรงพยาบาลเขตภาคกลางของประเทศไทย. วารสารกรมวิทยาศาสตร์ การแพทย์ 2559;58(1): 33–8.
Vedantham S, Karellas A, Vijayaraghavan GR, Kopans DB. Digital breast tomosynthesis: state of the art. Radiology 2015;277(3):663–84.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 วารสารการแพทย์และสาธารณสุข มหาวิทยาลัยอุบลราชธานี

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
เนื้อหาและข้อมูลในบทความที่ลงตีพิมพ์ในวารสารการแพทย์และสาธารณสุข มหาวิทยาลัยอุบลราชธานี ถือเป็นข้อคิดเห็นและความรับผิดชอบของผู้เขียนบทความโดยตรง ซึ่งกองบรรณาธิการวารสารไม่จำเป็นต้องเห็นด้วย หรือร่วมรับผิดชอบใด ๆ
บทความ ข้อมูล เนื้อหา รูปภาพ ฯลฯ ที่ได้รับการตีพิมพ์ในวารสารการแพทย์และสาธารณสุข มหาวิทยาลัยอุบลราชธานี ถือเป็นลิขสิทธิ์ของวารสารการแพทย์และสาธารณสุข มหาวิทยาลัยอุบลราชธานี กองบรรณาธิการไม่สงวนสิทธิ์ในการคัดลอกเพื่อการพัฒนางานด้านวิชาการ แต่ต้องได้รับการอ้างอิงที่ถูกต้องเหมาะสม