Altered Cast Impression Technique: A Case Report

Main Article Content

Tunyaporn Parmornsupornvichit

Abstract

Distal extension removable partial denture is one of the treatment of choices to replace missing teeth in Kennedy Class I and II partial edentulous patient. These dentures only have partial support from teeth as their bases may be extensions covering the ridge distal to the last abutment tooth. However, a mismatch between tissue resiliency at the distal extension base and teeth causes a rotational movement of the dentures, resulting in tooth damage, soft tissue ulceration and a residual ridge resorption. This case report describes patient who had difficulty to masticate the food. He would like to have dental prosthesis. Intra-oral examination shows partial edentulous arch in maxilla and mandible. Occlusal plane discrepancy. He received a maxillary removable partial denture, mandibular distal extension removable partial denture with altered cast impression technique to improve aesthetic and masticatory function, after treatment, patient is satisfied with aesthetic, pronunciation and mastication.

Article Details

How to Cite
1.
Parmornsupornvichit T. Altered Cast Impression Technique: A Case Report. crmj [internet]. 2021 Apr. 30 [cited 2025 Dec. 20];13(1):213. available from: https://he01.tci-thaijo.org/index.php/crmjournal/article/view/248344
Section
Case Report

References

1. Phoenix RD, Cagna DR, DeFreest CF and Stewart KL. Stewart's clinical removable partial prosthodontics. Chicago: Quintessence Pub; 2008.
2. Carr AB, McGivney GP, Brown DT. McCracken’s removable partial prosthodontics. St Louis: Elsevier; 2005.
3. Applegate OC. The partial denture base. J Prosthet Dent. 1955;5:636-48.
4. Steffel VL. Relining removable partial dentures for fit and function. J Prosthet Dent.1954;4(4):496-509.
5. Lee RE. Mucostatics. Dent Clin North Am. 1973;24:81-97.
6. Leupold RJ, Kratochvil FJ. An altered-cast procedure to improve tissue support for removable partial dentures. J Prosthet Dent. 1965;15:672-8.
7. Holmes JB. Influence of impression procedures and occlusal loading on partial denture movement. J Prosthet Dent. 1965;15:474-81.
8. Vahidi F. Vertical displacement of distal extension ridges by different impression techniques. J Prosthet Dent. 1978;40:374-7.
9. Hindel GW. Load distribution in extension saddle partial dentures. J Prosthet Dent. 1952;2:92-100.
10. Frank RP, Brudvik JS and Noonan CJ. Clinical outcome of the altered cast impression procedure compared with use of a one-piece cast. J Prosthet Dent. 2004;91(5):468-76.