Fit Abilities and Usability of Standard and Alternative Respirators for Small Face Health Workers in Thailand

Authors

  • Kansuda Bootsri Occupational Medicine Resident, Faculty of Medicine, Khon Kaen University
  • Phanumas Krisorn Department of Community, Family, and Occupational Medicine, Faculty of Medicine, Khon Kaen University

Keywords:

N95, KN95, KF94, fit abilities, usability

Abstract

Objective: To evaluate the fit abilities and usability of a NIOSH-approved N95, certified KN95, and KN94 respirators with a hook among Thai health workers who typically have small faces. Methods: A descriptive study was conducted involving 47 Thai health workers with small facial dimensions, as defined by the NIOSH Bivariate Panel. The study assessed the fit abilities and usability of both standard and alternative respirators, including the NIOSH-approved N95 respirator, as well as the KN95 and KF94 respirators, which are certified. Results:  The mean ± standard deviation fit factor values for each type of respirator were as follows: N95 = 125.9 ± 60.8, KN95 = 18.9 ± 8.53, and KF94 = 27.9 ± 22.7. In the fit criteria assessment, 61.7% of participants rated the N95 as providing a well-fitted feeling, compared to 14.9% for the KN95 and 12.8% for the KF94. In terms of comfortability, 42.6% of participants rated the N95 as the most comfortable, followed by 29.8% for KF94 and 25.6% for KN95. For breathability, 83.0% rated KF94 as the most breathable, followed by 72.3% for KN95 and 63.8% for N95. Conclusions: Only the N95 respirator passed the fit test and demonstrated appropriate fit abilities, including the highest rate of perceived well-fit feeling. In terms of usability, the N95 was rated as the most comfortable, while the KF94 was identified as the most breathable.

References

Chinese Center for Disease Control and Prevention. Guidelines for personal protection of specific groups from COVID-19. China CDC Weekly 2020;2(19):341–3.

Korea Centers for Disease Control and Prevention. Coronavirus disease 2019 response guidelines (for local governments). Sejong: Korea Centers for Disease Control and Prevention; 2020.

3M Company. Comparison of FFP2, KN95, and N95 filtering facepiece respirator classes [Internet]. 2021 [cited 2024 Jan 23]. Available from: https://shorturl.asia/43gJ0

Standardization Administration of the People’s Republic of China. Technical requirements for protective face mask for medical use (GB 19083-2010). Beijing: Standardization Administration of the People’s Republic of China; 2011.

Korea Ministry of Food and Drug Safety. Guideline on standards and specifications for filtering respirators (for industry). Sejong: Korea Ministry of Food and Drug Safety; 2019.

Occupational Safety and Health Administration (OSHA). Fit testing procedures (mandatory): 29 CFR 1910.134, Appendix A [Internet]. 2004 [cited 2025 Jan 23]. Available from: https://shorturl.asia/kU1qQ

National Institute for Occupational Safety and Health (NIOSH). Respirator approval program’s use of the NIOSH bivariate panel during isoamyl acetate fit testing beginning February 1, 2019 (NIOSH Conformity Assessment Notice CA 2019-1011). Atlanta (GA): Centers for Disease Control and Prevention; 2019.

Wadud A, Kitisubkanchana J, Santiwong P, Srithavaj MLT. Face proportions and analysis of maxillary anterior teeth and facial proportions in a Thai population. Open Dent J 2022;15(1):398–404.

Sangvichien S, Boonkaew K, Chuncharunee A, Komoltri C, Piyawinitwong S, Wongsawut A, et al. Sex determination in Thai skulls using craniometry: multiple logistic regression analysis. Siriraj Med J 2007;59(5):216–21.

Thapthim-On M, Chaiear N, Mitsungnern T. Which alternative well-fit masks can be used in medical procedures? J Infect Public Health 2024;17(2):204–11.

Suen LKP, Yang L, Ho SSK, Fung KHK, Boost MV, Wu CST, et al. Reliability of N95 respirators for respiratory protection before, during, and after nursing procedures. Am J Infect Control 2017;45(9):974-8.

Wangsan K, Sapbamrer R, Sirikul W, Kiratipaisarl W, Ongprasert K, Assavanopakun P, et al. Evaluating the fit and performance of flat-fold, cup, and three-panel respirators among Thai healthcare personnel. Front Public Health 2025;13:1561571.

Ng I, Kave B, Begg F, Bodas CR, Segal R, Williams D. N95 respirators: quantitative fit test pass rates and usability and comfort assessment by health care workers. Med J Aust 2022;217(2):88–93.

Dardas AZ, Serra Lopez VM, Boden LM, Gittings DJ, Heym K, Ahn J, et al. A simple surgical mask modification to pass N95 respirator-equivalent fit testing standards during the COVID-19 pandemic. PLoS One 2022;17(8).

Cloet A, Griffin L, Yu M, Durfee W. Design considerations for protective mask development: a remote mask usability evaluation. Appl Ergon 2022;102:103751.

Oestenstad RK, Bartolucci AA, Dillon HK. Effect of head strap design on the comfort and fit of respirators. J Occup Environ Hyg 2005;2(7):367–72.

Cichowicz J, Andrews A, Fries M. How to tell if your N95 respirator is NIOSH approved (DHHS [NIOSH] Publication No. 2021-124). Atlanta (GA): U.S. Department of Health and Human Services, CDC, NIOSH; 2021.

Zhuang Z, Coffey CC, Berry Ann R. The effect of subject characteristics and respirator features on respirator fit. J Occup Environ Hyg 2005;2(12):641–9.

Krah J, Shamblin M, Shaffer R. Filtering out confusion: frequently asked questions about respiratory protection and fit testing (DHHS [NIOSH] Publication No. 2018-129). Atlanta (GA): Centers for Disease Control and Prevention; 2018.

Karuppasamy KK, Obuchowski N. Comparison of fit for sealed and loose-fitting surgical masks and N95 filtering facepiece respirators. Ann Work Expo Health 2021;65(4):449–58.

Downloads

Published

2026-08-31

How to Cite

1.
Bootsri K, Krisorn P. Fit Abilities and Usability of Standard and Alternative Respirators for Small Face Health Workers in Thailand. JPMAT [internet]. 2026 Aug. 31 [cited 2026 Sep. 3];16(2):285-98. available from: https://he01.tci-thaijo.org/index.php/JPMAT/article/view/285206

Issue

Section

Original Article