Hb Bart’s and Hb E in cord blood : analysis using two automated Hb analyzers

Main Article Content

Jaruwan Tritipsombut
Kanokwan Sanchaisuriya
Goonnapa Fucharoen
Supan Fucharoen
Nirut Siriratmanawong
Charnchai Pinmuang-ngam
Yossombat Changtrakul
Pattara Sanchaisuriya

Abstract

At present, an automated hemoglobin (Hb) analyzer has been used widely for determining the Hb profiles. The aim of this study was to compare Hb Bart ‘s and Hb E levels obtained from the 2 different automated-HPLC-analyzers. One hundred and seventy-nine cord blood samples suspected of having Hb Bart’s and Hb E determined by the Primus CLC 330 (Primus Corp, MO, USA.) were recruited. These samples were analyzed again by the Variant Hemoglobin Testing System (Bio-Rad Laboratories, CA, USA.) in which the data processor was modified to quantify the amount of Hb Bart’s. All samples were investigated for α-thalassemia 1 (SEA and THAI deletions), α-thalassemia 2 (3.7 and 4.2 kb deletions), Hb Constant Spring (Hb CS) and Hb Paksé as well as Hb E genes. Analysis of the difference-values of Hb Bart’s and Hb E levels obtained from the 2 systems revealed a median (95% CI) of -0.2 (-0.3, -0.1) for Hb Bart’s and -0.15 (-0.3, -0.05) for Hb E indicating that these values were significantly different (P < 0.001 for Hb Bart’s and P = 0.008 for Hb E; Wilcoxon sign rank test). Comparison of Hb Bart’s and Hb E levels according to the thalassemia genotypes showed a lower trend of the values obtained from the Primus in almost all genotypes. However, statistical analysis of Hb Bart’s in a group of α-thalassemia 1 newborns showed no significant difference (11.7 ± 2.0 % vs 12.1 ± 2.5 %). The results indicated that Hb Bart’s level obtained from these 2 systems might be used comparatively for screening of α-thalassemia 1 in newborns.

Article Details

How to Cite
1.
Tritipsombut J, Sanchaisuriya K, Fucharoen G, Fucharoen S, Siriratmanawong N, Pinmuang-ngam C, Changtrakul Y, Sanchaisuriya P. Hb Bart’s and Hb E in cord blood : analysis using two automated Hb analyzers. Arch AHS [Internet]. 2010 Jan. 20 [cited 2024 Dec. 19];19(2). Available from: https://he01.tci-thaijo.org/index.php/ams/article/view/66103
Section
Original article
Author Biographies

Jaruwan Tritipsombut

The Graduate School; Centre for Research and Development of Medical Diagnostic Laboratories (CMDL), Faculty of Associated Medical Sciences, Khon Kaen University

Kanokwan Sanchaisuriya

Centre for Research and Development of Medical Diagnostic Laboratories (CMDL), Faculty of Associated Medical Sciences, Khon Kaen University

Goonnapa Fucharoen

Centre for Research and Development of Medical Diagnostic Laboratories (CMDL), Faculty of Associated Medical Sciences, Khon Kaen University

Supan Fucharoen

Centre for Research and Development of Medical Diagnostic Laboratories (CMDL), Faculty of Associated Medical Sciences, Khon Kaen University

Nirut Siriratmanawong

Regional Health Center 8, Nakhon Sawan province

Charnchai Pinmuang-ngam

Regional Health Center 8, Nakhon Sawan province

Yossombat Changtrakul

Microscopy Diagnostic unit, Srinagarind Hospital, Faculty of Medicine

Pattara Sanchaisuriya

Department of Nutrition, Faculty of Public Health, Khon Kaen University