Effectiveness of URiSCAN 2 ACR strip test for albuminuria detection in screening of kidney disease

Main Article Content

Laddawan Kateyam
Nattaya Sae-ung
Sirirat Anutrakulchai
Ubon Cha-on
Jureerut Daduang
Supakit Boonlakron
CKDNET Group

Abstract

Albuminuria is a key marker for detection of kidney disease and an increased risk factor for cardiovascular diseases. Measurement of albumin/creatinine ratio (ACR) in urine is the best screening method to detect albuminuria. Nowadays, new version of URiSCAN 2 ACR strip test is developed to measure of albumin/creatinine ratio in urine and to report ACR value as semi-quantitative and quantitative results. Thus, we aimed to validate the effectiveness of the URiSCAN 2 ACR strip test by comparing with a quantitative automated analyzer, and to demonstrate the effectiveness of the strip test for screening chronic kidney disease in the community population. Measurements of ACR levels in 484 spot urine specimens of participants in CKDNET project were performed using the URiSCAN 2 Optima urine chemistry test system and using the SYNCHRON Lx20 PRO automated chemistry analyzer. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of URiSCAN 2 ACR strip to detect ACR were 93.2%, 62.9%, 67.6%, 31.2% and 98.1%, respectively. URiSCAN 2 ACR strip showed 63.0% concordance rate with quantitative automated assay, 68.8% false-positive and only 1.9% false-negative results. In addition, the best cut-off of ACR value for detection of chronic kidney disease using the urine strip test was in the range from 29.50 to 33.00 mg/g with area under the curve of 0.7413, while the area under the curve of quantitative automated analyzer was 0.7515. Sensitivity, specificity and accuracy of the strip test for detection of chronic kidney disease were 70.5%, 61.8% and 63.8%, respectively. URiSCAN 2 ACR strip provided a high sensitivity, high negative predictive value and few false negative results for detection of albuminuria. Thus, this ACR strip test might be served as an optimal method to rule-out microalbuminuria. However, diagnostic performance of URiSCAN 2 ACR strip test at cut-off of ACR >30 mg/g is fair for screening CKD in community population.

Article Details

How to Cite
1.
Kateyam L, Sae-ung N, Anutrakulchai S, Cha-on U, Daduang J, Boonlakron S, Group C. Effectiveness of URiSCAN 2 ACR strip test for albuminuria detection in screening of kidney disease. Arch AHS [Internet]. 2020 Aug. 27 [cited 2024 Apr. 27];32(2):1-7. Available from: https://he01.tci-thaijo.org/index.php/ams/article/view/228690
Section
Original article

References

Garg JP, Bakris GL. Microalbuminuria: Marker of vascular dysfunction, risk factor for cardiovascular disease. Vasc Med 2002; 7(1): 35-43.

Gorriz JL, Martinez-Castelao A. Proteinuria: detection and role in native renal disease progression. Transplant Rev 2012; 26(1): 3-13.

Willis K, Cheung M, Slifer S. KDIGO 2012 clinical practice guideline for evaluation & management of CKD. Kidney Int Suppl 2013; 3(1): 19-62.

Lambers HJ, Gansevoort RT, Brenner BM, Cooper ME, Parving HH, Shahinfar S, et al. Comparison of different measures of urinary protein excretion for prediction of renal events. J Am Soc Nephrol 2010; 21(8): 1355-60.

Pathania M, Rathaur VK, Yadav N, Jayara A, Chaturvedi A. Quantitative micro-albuminuria assessment from “random voided urinary albumin: creatinine ratio” versus “24 hours urinary albumin concentration” for screening of diabetic nephropathy. J Clin Diagnostic Res 2013; 7(12): 2828-31.

Pugia MJ. Technology behind diagnostic reagent strips. Lab Med 2000; 31(2): 92-6.

Glassock RJ. Is the presence of microalbuminuria a relevant marker of kidney disease. Curr Hypertens Rep 2010; 12(5): 364-8.

Vassalotti JA, Stevens LA, Levey AS. Testing for chronic kidney disease: A position statement from the national kidney foundation. Am J Kidney Dis 2007; 50(2): 169-80.

Lim S, Yu HJ, Lee S, Park H, Kwon MJ, Woo HY. Evaluation of the URiSCAN 2 ACR strip to estimate the urine albumin/creatinine ratios. J Clin Lab Anal 2018; 32(3): 6-11.

Cho MC, Ji M, Kim SY, Choe W, Lee W, Chun S, et al. Evaluation of the URiSCAN super cassette ACR semiquantitative urine dipstick for microalbuminuria screening. J Clin Lab Anal 2014; 28(4): 281-6.

Cowart SL, Stachura ME. Glucosuria. In: Walker HK, Hall WD, Hurst JW, editors. Clinical methods: the history, physical, and laboratory examinations. 3rd ed. Boston: Butterworths; 1990.

Wilde HM, Banks D, Larsen CL, Connors G, Wallace D, Lyon ME. Evaluation of the Bayer® microalbumin/creatinine urinalysis dipstick. Clin Chim Acta 2008; 393(2): 110-3.

Larson TS. Evaluation of proteinuria. Mayo Clin Proc 1994; 69(12): 1154-8.

Boulatov VA, Stenehjem A, Os I. Association between albumin: creatinine ratio and 24-hour ambulatory blood pressure in essential hypertension. Am J Hypertens 2001; 14(4 I): 338-44.

Bianchi S, Bigazzi R, Campese VM. Microalbuminuria in essential hypertension: significance, pathophysiology, and therapeutic implications. Am J Kidney Dis 1999; 34(6): 973-95.

Lin YP. Albuminuria in hypertension. Hypertens Res 2013; 36(9): 762-4.

Christenson RH. Evidence-based laboratory medicine - A guide for critical evaluation of in vitro laboratory testing. Ann Clin Biochem 2007; 44(2): 111-30.

Guy M, Newall R, Borzomato J, Kalra PA, Price C. Diagnostic accuracy of the urinary albumin: creatinine ratio determined by the CLINITEK Microalbumin and DCA 2000+ for the rule-out of albuminuria in chronic kidney disease. Clin Chim Acta 2009; 399(1–2): 54-8.

Graziani MS, Gambaro G, Mantovani L, Sorio A, Yabarek T, Abaterusso C, et al. Diagnostic accuracy of a reagent strip for assessing urinary albumin excretion in the general population. Nephrol Dial Transplant 2009; 24(5): 1490-4.

Nah EH, Cho S, Kim S, Cho HI. Comparison of urine albumin-to-creatinine ratio (ACR) between acr strip test and quantitative test in prediabetes and diabetes. Ann Lab Med 2017; 37(1): 28-33.

Wu HY, Peng Y Sen, Chiang CK, Huang JW, Hung KY, Wu KD, et al. Diagnostic performance of random urine samples using albumin concentration vs ratio of albumin to creatinine for microalbuminuria screening in patients with diabetes mellitus: A systematic review and meta-analysis. JAMA Intern Med 2014; 174(7): 1108-15.