Construction of gelatin-based breast model for practicing in breast ultrasound
Main Article Content
Abstract
Background: Breast ultrasound plays a vital role in detecting breast lesions. However, breast ultrasound requires the expertise and great skills of medical personnel. However, training medical personnel on live patients is still impractical. Therefore, simulation-based training on a phantom is necessary.
Objectives: To develop a breast model for lesion detection for use in ultrasound breast training.
Methods: Firstly, the samples of the gelatin-based model were constructed in five samples in different concentrations of gelatin, and then a sample that was closest to the elastic modulus of breast tissue was selected to make a model. Three breast models were made including a non-pathologic model, a pathologic model with a paraffin wax mass, and a fluid cyst model. After that, 36 female 4th-year radiologic technology students were asked to rate their skills before and after training and their satisfaction.
Results: The result showed that the breast models were successfully made of gelatin, which represents a soft and elastic texture, is stable at room temperature, and nearly matched the elastic modulus of breast tissue. The evaluation of our breast model showed that it was a good training model, resulting in a significant increase in exercise skills after using the breast model (p<.05). Moreover, overall breast model appearance and pilot tests showed a good level of satisfaction.
Conclusions: Our gelatin-based breast models can be used as a training tool for practicing breast ultrasound examinations.
Downloads
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของวิทยาลัยพยาบาลบรมราชชนนี จังหวัดนนทบุรี
ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับวิทยาลัยพยาบาลบรมราชชนนี จังหวัดนนทบุรี และคณาจารย์ท่านอื่น ในวิทยาลัยฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใด ๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว
References
Cancer register unit, Medical Digital division National Cancer Institute. Hospital-based cancer registry 2019. Bangkok: New Thammada Press; 2020. (in Thai).
Urairoekkun C. Breast cancer screening [Internet]. 2019 [cited 2020 Feb 11]; Available from: http://doh.hpc.go.th/bs/ topicDisplay.php?id=134. (in Thai).
National Cancer Institute. Breast cancer screening (PDQ®)-health professional version [Internet]. 2018 [cited 2020 Feb 11]; Available from: https://www.cancer.gov/ types/breast/hp/.
Thanyarak Breast Centre, Breast Foundation Under the Patronage of HRH The Princess Mother. Training manual of targeted breast ultrasound [Internet]. 2017 [cited 2020 Feb 11]; Available from: http://doh.hpc.go.th/ data/bse/targetUS.pdf. (in Thai).
Richardson C, Bernard S, Dinh VA. A Cost-effective, gelatin-based phantom model for learning ultrasound-guided fine-needle aspiration procedures of the head and neck. J Ultrasound Med. 2015;34(8): 1479–84. doi: 10.7863ultra.34.8.1479.
Jheng Y, Lin C. "Fabrication and testing of breast tissue-mimicking phantom for needle biopsy cutting: A pilot study." Proceedings of the 2017 Design of Medical Devices Conference. 2017 Design of Medical Devices Conference. 10–13 April 2017; Minneapolis, Minnesota, USA. doi: 10.1115/DMD2017-3505.
Madsen EL, Zagzebski JA, Banjavie RA, Jutila RE. Tissue mimicking materials for ultrasound phantoms. Med Phys. 1978;5 (5):391-4. doi:10.1118/1.594483.
Madsen EL, Zagzebski JA, Frank GR. Oil-in-gelatin dispersions for use as ultrasonically tissue-mimicking materials. Ultrasound Med Biol. 1982;8(3):277-87. doi: 10.1016/0301-5629(82)90034-5.
Di Meo S, Pasotti L, Iliopoulos I, Pasian M, Ettorre M, Zhadobov M, et al. Tissue-mimicking materials for breast phantoms up to 50 GHz. Phys Med Biol. 2019;64(5): 055006. doi: 10.1088/1361-6560/aafeeec.
Ng SY, Kuo YL, Lin CL. Low-cost and easily fabricated ultrasound-guided breast phantom for breast biopsy training. Appl. Sci. 2021;11(16):7728. doi: 10.3390/app11167728.
Erler-Zimmer GmbH &Co.KG Ultrasound-guided breast biopsy phantom (Set of one basic and one advanced breast) [Internet]. 2020 [cited 2020 Mar 10]; Available from: https://www.erler-zimmer.de/shop/en/10157.
Sawasdiraksa A. Materials development and design of heel cushion for reducing
plantar heel pressure [Dissertation]. Songkhla. Prince of Songkla University; 2010. (in Thai).
Manickam K, Reddy MR, Seshadri S, Raghavan B. Development of a training phantom for compression breast elastography -comparison of various elastography systems and numerical simulations. J Med Imaging (Bellingham). 2015;2(4):047002. doi: 10. 1117/1.JMI.2.4.047002.
Sayorwan W, Phaekhunthot S, Chumworathayee P, Udompittayason J. Development of a 3D para rubber model for practicing massage skill of TTM students of Kanchanabhisek institute of Medical and Public Health Technology. Journal of Nursing and Education. 2017;10(3):71–82. (in Thai).
Srisa-ard B. Basic research. 9th ed. Bangkok: Suweeriyasan Publishing; 2013.
Krouskop TA, Wheeler TM, Kallel F, Garra BS, Hall T. Elastic moduli of breast and prostate tissues under compression. Ultrason Imaging. 1998;20(4):260–74. doi: 10. 1177/016173469802000403.
Ramião NG, Martins PS, Rynkevic R, Fernandes AA, Barroso M, Santos DC. Biomechanical properties of breast tissue, a state-of-the-art review. Biomech Model Mechanobiol. 2016;15(5):1307–23. doi: 10.1 007/s10237-016-0763-8.
Culjat MO, Goldenberg D, Tewari P, Singh RS. A review of tissue substitutes for ultrasound imaging. Ultrasound Med Biol. 2010;36(6):861 -73. doi: 10.1016/j.Ultrasmedbio.2010.02.012.