Standard plan for low dose rate Cs-137
Abstract
The standard treatment plan for low dose rate Cs-137 ideal insertion of carcinoma of cervix has been used for patients in some hospital due to the limitation of time and treatment planning system. To study that individualisation calculation is different or comparable to the standard plan, the treatment plans of 15 patients were selected to compare the calculated dose rate at point A with the standard dose rate. The patients were treated with the standard applicator of 5-6 cm uterine tube long and a pair of ovoids of half small, small or medium size. The insertions were done two times about 2 weeks separation. The loading followed to the Manchester system. The study for 30 insertions showed the average calculated dose rate at point A of 158.58+11.95 cGy/hr compare to the standard dose rate of 155.01 cGy/hr. The average dose rate at point B is 46.23+2.75 cGy/hr which is 29.15% of point A. The dose rate at point A varies from 146.02 cGy/hr to 199.45 cGy/hr which 22 of 30 insertions (73.3%) have the dose rate at point A within 5% of the standard dose rate. The standard dose rate can be used only if the cephalad surface of ovoids are in the same level with the flange of uterine tube. However, the anatomy and the extension of the disease including the skill of the insertor are the limitation factors.
References
Tod M, Meredith WJ. Treatment of cancer of the cervix uteri - a revised "Manchester method". Br J Radiol 1953 ; 26 : 252.
Wilkinson JM, Moore CJ, Notley HM, Hunter RD. The use of Selectron afterloading equip- ment to simulate and extend the Manchester System for intracavitary therapy of the cervix uteri. Br J Radial 1983 ; 409-414.
ICRU Report No. 38, Dose and volume speci- fication for reporting intracavitary therapy in gynecology, Chassagne D, Dutreix A et al (eds). International Commision on Radiation Units and Measurements : Bethesda 1985.
Herbolsheimer M. Is individual treatment planning in gynaecological brachytherapy necessary? In : Mould RF, Muller RP, eds. Brachytherapy in Germany. Wageningen : Nucletron 1993 ; 145-155.
Downloads
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของวารสารมะเร็งวิวัฒน์ ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับ และบุคคลากรท่านอื่น ๆ ใน สมาคมฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใดๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว