Clinical Considerations for Mini Dental Implant Assisted Removable Partial Denture

Main Article Content

Wiphatpong Bumrungsiri
Kullapop Suttiat
Chaiy Rungsiyakull
Pimduen Rungsiyakull

Abstract

In the present, mini dental implants are applied for supporting or retaining removable partial denture, especially in patients with a bone limitation for conventional dental implant placement. When considering the literature on the mini dental implant-assisted removable partial denture, most studies are unclear, particularly linical considerations. In an attempt to clarify these uncertainties, the topic of the biomechanics of dental implant-assisted removable partial denture and clinical considerations have been summarized and discussed 106 literatures in this review.

Article Details

How to Cite
Bumrungsiri, W. ., Suttiat, K. ., Rungsiyakull, C. ., & Rungsiyakull, P. . (2019). Clinical Considerations for Mini Dental Implant Assisted Removable Partial Denture. Chiang Mai Dental Journal, 40(1), 13–30. Retrieved from https://he01.tci-thaijo.org/index.php/cmdj/article/view/192543
Section
Review article

References

กรมอนามัย ส. รายงานผลการสำรวจสภาวะสุขภาพช่องปากระดับประเทศ ครั้งที่ 7 ประเทศไทย พ.ศ. 2555: สำนักงานกิจการ โรงพิมพ์องค์การสงเคราะห์ทหารผ่านศึก; 2556.

Friedman PK, Lamster IB. Tooth loss as a predictor of shortened longevity: exploring the hypothesis. Periodontol 2000 2016; 72(1): 142-152.

Mittal S, Tewari S, Goel R. Esthetic and functional rehabilitation of mutilated dentition and loss of vertical dimension due to amelogenesis imperfecta. Indian J Dent 2014; 5(2): 102-106.

Wang MQ, Xue F, He JJ, Chen JH, Chen CS, Raustia A. Missing posterior teeth and risk of temporomandibular disorders. J Dent Res 2009; 88(10): 942-945.

Costa MD, Froes Junior GdRT, Santos CN. Evaluation of occlusal factors in patients with temporomandibular joint disorder. Dental Press J Orthod 2012; 17(6): 61-68.

Gupta K, Javiya P, Kumar P, Mallikarjuna R. Rehabilitation of lost vertical dimension with cast post core and cast partial denture. BMJ Case Rep 2013; 2013: 1-4.

Wetherell JD, Smales RJ. Partial denture failures: a long-term clinical survey. J Dent (Shiraz) 1980; 8(4): 333-340.

Keltjens HMAM, Kayser AF, Hertel R, Battistuzzi PGFCM. Distal extension removable partial dentures dupported by implants and residual teeth: considerations and case reports. Int J Oral Maxillofac Implants 1993; 8(2): 68-77.

Halterman SM, Keith JD, Nelson DR, Rivers JA. Implant Support for Removable Partial Overdentures: a Case Report. Implant Dent 1999; 8(1): 74-78.

Karas S, Mijiritsky E. Removable partial denture design involving teeth and implants as an alternative to unsuccessful fixed implant therapy: a case report. Implant Dent 2004; 13(3): 218-222.

Klinger A, Mardinger O, Mijiritsky E, Ormianer Z. Use of dental implants to improve unfavorable removable partial denture design. Compend Contin Educ Dent 2005; 26(10) :744-746.

Mitrani R, Brudvik JS, Phillips KM. Posterior implants for distal extension removable prostheses: a retrospective study. Int J Periodontics Restorative Dent 2003; 23(4): 352-359.

Threeburuth W, Khongkhunthian P. The use of immediated-load mini dental implant to retain mandibular distal-extension removable partial denture: a preliminary prospective clinical study results. CM Dent J 2017; 39(2): 75-85. (in Thai)

De Souza RF, Ribeiro AB, Della Vecchia MP, et al. Mini vs. standard implants for mandibular overdentures: a randomized trial. J Dent Res 2015; 94(10): 1376-1384.

Schwindling FS, Schwindling F-P. Original article: Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis. J Prosthodont Res 2015; 60(3): 193-198.

Mostafa Omran AA, Amr Elkarargy , Mahmoud Sallom Mini-implant overdenture versus conventional implant overdenture (a radiographic and clinical assessments). J Am Sci 2013; 9(9): 89-97.

Kanazawa M, Feine J, Esfandiari S. Clinical guidelines and procedures for provision of mandibular overdentures on 4 mini-dental implants. J Prosthet Dent 2016; 117(1) :22-27.

Flanagan D, Mascolo A. The mini dental implant in fixed and removable prosthetics: a review. J Oral Implantol 2011; 37 (1): 123-132.

Christensen GJ, Swift EJ. Mini implants: good or bad for long-term service? J Esthet Dent 2008; 20(5): 343-348.

คณะอนุกรรมการพัฒนาวิชาการ. คู่มือการทำรากเทียมสำหรับฟันเทียมทั้งปากชิ้นล่าง. 2008. นนทบุรี ประเทศไทย: สำนักงานโครงการรากเทียม สถาบันทันตกรรม.

Zygogiannis K, Wismeijer D, Parsa A. A pilot study on mandibular overdentures retained by mini dental implants: marginal bone level changes and patient-based ratings of clinical outcome. Int J Oral Maxillofac Implants 2016; 31(5): 1171-1178.

Kunavisarut C, Kumpirichaya R. Short-term evaluation of mini-implant retained removable partial denture. M Dent J 2014; 34(3): 215-224.

Christensen GJ. The ‘mini'-implant has arrived. JADA 2006; 137(3): 387-390.

Laney WR. Glossary of oral and maxillofacial implants. Int J Oral Maxillofac Implants 2017; 32(4) :1-199.

Keith JF, Steven MM, Carl FD et al. The glossary of prosthodontic terms: ninth edition. J Prosthodont 2017; 117(5) :1-105.

Mijiritsky E, Lorean A, Mazor Z, Levin L. Implant tooth-supported removable partial denture with at least 15-year long-term follow-up. Clin Implant Dent Relat Res 2015; 17(5): 917-922.

Grossmann Y, Nissan J, Levin L. Clinical effectiveness of implant-supported removable partial dentures: a review of the literature and retrospective case evaluation. J Oral Maxillofac Surg 2009; 67(9): 1941-1946.

Kaufmann R, Friedli M, Hug S, Mericske-Stern R. Removable dentures with implant support in strategic positions followed for up to 8 years. Int J Prosthodont 2009; 22(3): 233-241.

Manderson R, Wills D, Picton D, editors. Biomechanics of denture-supporting tissues. Proceedings of the 2nd International Prosthodontic Congress; 1979: The CV Mosby St. Louis, Mo, USA.

Ellakwa A. Damage caused by removable partial dentures: reality. Int J Dent 2012; 2(4): 107-108.

Rocha EP, Francisco SB, Del Bel Cury AA, Cury JA. Longitudinal study of the influence of removable partial denture and chemical control on the levels of Streptococcus mutans in saliva. J Oral Rehabil 2003; 30(2): 131-138.

Verri FR, Pellizzer EP, Pereira JA, Zuim PR, Santiago Junior JF. Evaluation of bone insertion level of support teeth in class I mandibular removable partial denture associated with an osseointegrated implant: a study using finite element analysis. Implant Dent 2011; 20(3): 192-201.

de Freitas RF, de Carvalho Dias K, da Fonte Porto Carreiro A, Barbosa GA, Ferreira MA. Mandibular implant-supported removable partial denture with distal extension: a systematic review. J Oral Rehabil 2012; 39(10) :791-798.

Zancope K, Abrao GM, Karam FK, Neves FD. Placement of a distal implant to convert a mandibular removable Kennedy class I to an implant-supported partial removable Class III dental prosthesis: A systematic review. J Prosthet Dent 2015; 113(6): 528-533.

Ohkubo C, Kobayashi M, Suzuki Y, Hosoi T. Effect of implant support on distal-extension removable partial dentures: in vivo assessment. Int J Oral Maxillofac Implants 2008; 23(6): 1095-1101.

Carr AB, Brown DT. CHAPTER 25 - Considerations for the use of dental implants with removable partial dentures. McCracken's Removable Partial Prosthodontics (Twelfth Edition). 12 ed. Saint Louis: Mosby; 2011: 338-345.

Quirynen M, Naert I, Steenberghe D, Dekeyser C, Callens A. Periodontal aspects of osseointegrated fixtures supporting a partial bridge. J Clin Periodontol 1992; 19(2): 118-126.

Cox JF, Zarb GA. The longitudinal clinical efficacy of osseointegrated dental implants: a 3-year report. Int J Oral Maxillofac Implants 1987; 2(2): 38-59.

Adell R, Eriksson B, Lekholm U, Brånemark P-I, Jemt T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990; 5(4): 1-26.

Ahlqvist J, Borg K, Gunne J, Nilson H, Olsson M, Astrand P. Osseointegrated implants in edentulous jaws: a 2-year longitudinal study. Int J Oral Maxillofac Implants 1990; 5(2): 155-163.

Oh WS, Oh TJ, Park JM. Impact of implant support on mandibular free-end base removable partial denture: theoretical study. Clin Oral Implants Res 2016; 27(2) :87-90.

Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol 2002; 73(3): 322-333.

Jemt T, Lekholm U, Adell R. Osseointegreated implants in the treatment of partially edentulous patients: a preliminary study on 876 consecutively placed fixtures. Int J Oral Maxillofac Implants 1989; 4(3): 44-58.

Lindquist LW, Rockler B, Carlsson GE. Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses. J Prosthet Dent 1988; 59(1): 59-63.

Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. part II: prosthetic aspects. J Prosthet Dent 1992; 68(6): 949-956.

Duyck J, Naert I, Ronold HJ, Ellingsen JE, Van Oosterwyck H, Vander Sloten J. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Implants Res 2001; 12(3): 207-218.

Sahin S, Cehreli MC, Yalcın E. Review: The influence of functional forces on the biomechanics of implant-supported prostheses—a review. J Dent (Shiraz) 2002; 30(7-8): 271-282.

Bourauel C, Aitlahrach M, Heinemann F, Hasan I. Biomechanical finite element analysis of small diameter and short dental implants: extensive study of commercial implants. Biomed Tech (Berl) 2012; 57(1): 21-32.

Sakka S, Baroudi K, Nassani MZ. Factors associated with early and late failure of dental implants. J Investig Clin Dent 2012; 3(4): 258-261.

Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent 2004; 91(1): 20-25.

Tuncelli B, Poyrazoglu E, Koyluoglu AM, Tezcan S. Comparison of load transfer by implant abutments of various diameters. Eur J Prosthodont Restor Dent 1997; 5(2): 79-83.

Coelho Goiato M, Pesqueira AA, Santos DMD, Haddad MF, Moreno A. Photoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wide. J Clin Diagn Res 2014; 8(9): 86-90.

Turkyilmaz I. Use of distal implants to support and increase retention of a removable partial denture: a case report. J Can Dent Assoc 2009; 75(9): 655-658.

Albrektsson T, Zarb G, Worthington P, Eriksson A. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986; 1(1): 11-25.

Smith DE, Zarb GA. Criteria for success of osseointegrated endosseous implants. J Prosthet Dent 1989; 62(5): 567-572.

Mijiritsky E, Ormianer Z, Klinger A, Mardinger O. Use of dental implants to improve unfavorable removable partial denture design. Compend Contin Educ Dent 2005; 26(10) :586-590

Pimentel MJ, Arrellaga JP, Bacchi A, Del Bel Cury AA. The use of implants to improve removable partial denture function. J Indian Prosthodont Soc 2014; 14(1): 243-247.

Hegazy SA, Elshahawi IM, Elmotayam H. Stresses induced by mesially and distally placed implants to retain a mandibular distal-extension removable partial overdenture: a comparative study. Int J Oral Maxillofac Implants 2013; 28(2): 403-407.

Memari Y, Geramy A, Fayaz A, Rezvani Habib Abadi S, Mansouri Y. Influence of implant position on stress distribution in implant-assisted distal extension removable partial dentures: a 3D finite element analysis. J Dent (Tehran) 2014; 11(5): 523-530.

Cunha LD, Pellizzer EP, Verri FR, Pereira JA. Evaluation of the influence of location of osseointegrated implants associated with mandibular removable partial dentures. Implant Dent 2008; 17(3): 278-287.

Lee J-H, Frias V, Lee K-W, Wright RF. Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 2005; 94(4): 377-381.

Olate S, Lyrio MC, de Moraes M, Mazzonetto R, Moreira RW. Influence of diameter and length of implant on early dental implant failure. J Oral Maxillofac Surg 2010; 68(2): 414-419.

Calvo-Guirado JL, Lopez Torres JA, Dard M, Javed F, Perez-Albacete Martinez C, Mate Sanchez de Val JE. Evaluation of extrashort 4-mm implants in mandibular edentulous patients with reduced bone height in comparison with standard implants: a 12-month results. Clin Oral Implants Res 2016; 27(7): 867-874.

Verri FR, Pellizzer EP, Rocha EP, Pereira JA. Influence of length and diameter of implants associated with distal extension removable partial dentures. Implant Dent 2007; 16(3): 270-280.

Barikani H, Rashtak S, Akbari S, Badri S, Daneshparvar N, Rokn A. The Effect of Implant Length and Diameter on the Primary Stability in Different Bone Types. J Dent (Tehran) 2013; 10(5): 449-455.

Bataineh AB, Al-dakes AM. The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis. J Clin Exp Dent 2017; 9(1): 1-6.

Hsu J-T, Wu AY-J, Fuh L-J, Huang H-L. Effects of implant length and 3D bone-to-implant contact on initial stabilities of dental implant: a microcomputed tomography study. BMC Oral Health 2017; 17(1): 9-24.

Barikani H, Rashtak S, Akbari S, Fard MK, Rokn A. The effect of shape, length and diameter of implants on primary stability based on resonance frequency analysis. Dent Res J (Isfahan) 2014; 11(1): 87-91.

Patel PB. Narrow-diameter implants: A minimally invasive solution for overdenture treatment - part 2. Aust Dent Pract 2013; 24(2): 160.

Mundt T, Schwahn C, Stark T, Biffar R. Clinical response of edentulous people treated with mini dental implants in nine dental practices. Gerodontology 2015; 32(3): 179-187.

Garhnayak M, Garhnayak L, Dev S, Kar AK, Mohapatra A. Prosthodontic management of flat mandibular ridge by mini implant supported over denture. J Clin Diagn Res 2014; 8(7): 19-21.

Esfandiari S, Feine J, Mushantat A, Sohrabi K. How successful are small‐diameter implants? a literature review. Clin Oral Implants Res 2012; 23(5): 515-525.

Scepanovic M, Calvo-Guirado JL, Markovic A, et al. A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants. Eur J Oral Implantol 2012; 5(4): 367-379.

Jackson BJ. Small-Diameter Implant Treatment Plan Revision: Management of Complications. J Oral Implantol 2016; 42(3): 295-298.

Maryod WH, Ali SM, Shawky AF. Immediate Versus Early Loading of Mini-Implants Supporting Mandibular Overdentures: A Preliminary 3-Year Clinical Outcome Report. Int J Prosthodont 2014; 27(6): 553-560.

Ashmawy TM, El Talawy DB, Shaheen NH. Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food. Quintessence Int 2014; 45(8): 663-671.

Jankowski IM. The effect of maximum bite force on marginal bone loss of mini-implants supporting a mandibular overdenture: a randomized controlled trial. Clin Oral Impl Res 2010; 21(2): 243-249.

Shahmiri R, Das R, Aarts JM, Bennani V. Finite element analysis of an implant-assisted removable partial denture during bilateral loading: occlusal rests position. J Prosthet Dent 2014; 112(5): 1126-1133.

Shahmiri R, Aarts JM, Bennani V, Atieh MA, Swain MV. Finite Element Analysis of an Implant-Assisted Removable Partial Denture. J Prosthodont 2013; 22(7): 550-555.

limpattamapanee S. Implant for removable denture. CM Dent J 2016; 37(1): 27-44. (in Thai)

Omura AJ, Latthe V, Marin MM, Cagna DR. Implant-assisted removable partial dentures: practical considerations. Gen Dent 2016; 64(6): 38-45.

Watanabe F, Hata Y, Komatsu S, Ramos TC, Fukuda H. Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution. Odontology 2003; 91(1): 31-36.

Elsyad MA, Setta FA, Khirallah AS. Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study. J Adv Prosthodont 2016; 8(2): 116-124.

Patel PB. Narrow-diameter implants: A minimally invasive solution for overdenture treatment - part 1. Aust Dent Pract 2013; 24(2): 160-164.

Zest Anchors L. Locator® implant attachment quick reference guide. Zest Anchors, LLC; 2017:1-36.

Blatterfein L. The use of the semiprecision rest in removable partial dentures. J Prosthodont 1969; 22(3): 307-332.

Ben-Ur Z, Shifman A, Aviv I, Gorfil C. Further aspects of design for distal extension removable partial dentures based on the Kennedy classification. J Oral Rehabil 1999; 26(2): 165-169.

Nakamura Y, Kanbara R, Ochiai KT, Tanaka Y. A finite element evaluation of mechanical function for 3 distal extension partial dental prosthesis designs with a 3-dimensional nonlinear method for modeling soft tissue. J Prosthet Dent 2014; 112(4): 972-980.

Carr AB, Brown DT. Principles of removable partial denture design. Removable Partial Prosthodontics (Twelfth Edition). Saint Louis: Mosby; 2011: 115-129.

Demer WJ. An analysis of mesial rest-I-bar clasp designs. J Prosthet Dent 1976; 36(3): 243-253.

Mizuuchi W, Yatabe M, Sato M, Nishiyama A, Ohyama T. The effects of loading locations and direct retainers on the movements of the abutment tooth and denture base of removable partial dentures. J Med Dent Sci 2002; 49(1): 11-18.

Zach GA. Advantages of mesial rests for removable partial dentures. J Prosthet Dent 1975; 33(1): 32-35.

Hanako S, Kei K, Ryoichi H, Tsunemoto K, Keiichi S. Effects of occlusal rest design on pressure distribution beneath the denture base of a distal extension removable partial denture—an in vivo study. Int J Prosthodont 2014; 27(5): 469-471.

Implant-assisted removable partial denture: an approach to switch Kennedy Class I to Kennedy Class III. Wolters Kluwer India Pvt Ltd; 2016: 408-411.

Drago C, Howell K. Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses. J Prosthodont 2012; 21(5): 413-424.

Carr AB, Brown DT. CHAPTER 17 - Occlusal relationships for removable partial dentures. McCracken's Removable Partial Prosthodontics (Twelfth Edition). 12 ed. Saint Louis: Mosby; 2011:242-252.

Rangert B, Sennerby L, Meredith N, Brunski J. Design, maintenance and biomechanical considerations in implant placement. Dent Update 1997; 24(10): 416-420.

Kaukinen JA, Edge MJ, Lang BR. The influence of occlusal design on simulated masticatory forces transferred to implant-retained prostheses and supporting bone. J Prosthet Dent 1996; 76(1): 50-55.

Weinberg LA, Kruger B. A comparison of implant/prosthesis loading with four clinical variables. Int J Prosthodont 1995; 8(5): 421-433.

Christensen FT. Mandibular free end denture. J Prosthodont 1962; 12(1): 111-115.

Bulard RA, Vance JB. Multi-clinic evaluation using mini-dental implants for long-term denture stabilization: a preliminary biometric evaluation. Compend Contin Educ Dent 2005; 26(12): 892-897.

Elsyad M, Gebreel A, Fouad M, Elshoukouki A. The clinical and radiographic outcome of immediately loaded mini implants supporting a mandibular overdenture. A 3‐ year prospective study. J Oral Rehabil 2011; 38(11): 827-834.

Ahn M-R, An K-M, Choi J-H, Sohn D-S. Immediate loading with mini dental implants in the fully edentulous mandible. Implant Dent 2004; 13(4): 367-372.

Vercruyssen M, Marcelis K, Coucke W, Naert I, Quirynen M. Long‐term, retrospective evaluation (implant and patient‐centred outcome) of the two‐implants‐supported overdenture in the mandible. Part 1: survival rate. Clin Oral Impl Res 2010; 21(4): 357-365.

Dantas IdS, de Souza MBC, Morais MHdST, Carreiro AdFP, Barbosa GAS. Success and survival rates of mandibular overdentures supported by two or four implants: a systematic review. 2014:74-80.

Romeo E, Lops D, Margutti E, Ghisolfi M, Chiapasco M, Vogel G. Long-term survival and success of oral implants in the treatment of full and partial arches: a 7-year prospective study with the ITI dental implant system. Int J Oral Maxillofac Implants 2004; 19(2): 247-259.