Comparative Study on The Shaping Ability of Three Reciprocating Nickel-Titanium Single File Systems in Curved Root Canals

Main Article Content

Phanthanan Sanguanwongthong
Peeraporn Taweewattanapaisan
Jaruma Sakdee
Chinalai Piyachon

Abstract

The purpose of this study was to compare the shaping ability of Reciproc® blue, WaveOne® Gold and EdgeOne Fire™ Reciprocating nickel-titanium single file systems in curved root canals. A total of 45 root canals in extracted human teeth with angles of curvatures ranging from 20-40 degrees and radii ranging between 5-9 mm were divided into 3 groups (n = 15). The degree of canal transportation distances were evaluated using micro-computed tomography (Micro-CT). The percent change of degree of canal curvature after root canal preparation was also evaluated using digital radiography. The overall preparation times were recorded. The degree of canal transportation distances and percent change of degree of canal curvature after canal preparation were analyzed statistically using the Kruskal–Wallis test. The preparation times were analyzed using One-Way ANOVA with a 95% confidence level. The results showed no statistically significant differences in the degree of canal transportation distances and preparation times between 3 groups. The EdgeOne Fire™ system recorded a more statistically significant percent change of canal curvature than the WaveOne® Gold system. The mean preparation time was 72.1-74.4 seconds per canal. In conclusion, the 3 groups of Reciprocating nickel-titanium single file systems showed favorable results in terms of the shaping ability of curved root canals. All groups produced only minor changes in canal curvature, while the EdgeOne Fire™ system showed more of a decrease in the angle of canal curvature than the WaveOne® Gold system.

Article Details

How to Cite
1.
Sanguanwongthong P, Taweewattanapaisan P, Sakdee J, Piyachon C. Comparative Study on The Shaping Ability of Three Reciprocating Nickel-Titanium Single File Systems in Curved Root Canals. Khon Kaen Dent J [Internet]. 2020 Dec. 16 [cited 2024 Mar. 29];23(3):1-10. Available from: https://he01.tci-thaijo.org/index.php/KDJ/article/view/243450
Section
Research Articles
Share |

References

Kuhn G, Jordan L. Fatigue and mechanical properties of nickel-titanium endodontic instruments. J Endod 2002; 28(10):716-20.

Esposito PT, Cunningham CJ. A comparison of canal preparation with nickel-titanium and stainless steel instruments. J Endod 1995;21(4):173-6.

Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30(8):559-67.

Burklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single‐file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2012;45(5):449-61.

Roane JB, Sabala CL, Duncanson MG. The “balanced force” concept for instrumentation of curved canals. J Endod 1985;11(5):203-11.

De-Deus G, Silva EJNL, Vieira VTL, Belladonna FG, Elias CN, Plotino G, et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. J Endod 2017;43(3):462-6.

Keskin C, Demiral M, Sarıyılmaz E. Comparison of the shaping ability of novel thermally treated Reciprocating instruments. Restor Dent Endod 2018;43(2):e15.

Webber J. Shaping canals with confidence: WaveOne GOLD single-file Reciprocating system. Roots 2015;1:34-40.

EdgeOne Fire. [homepage on the Internet]. New Mexico: EdgeEndo; c2012-9 [updated 2019 Dec 1; cited 2020 Jan 9]. Available from:https://web.edgeendo.com/ edgeonefire/.

Saberi E, Farhad MN, Bijari S, Daryaeian M. Comparative evaluation of root canal transportation by three NiTi single-file systems in curved canals: a cone beam computed tomography study. Int J dent 2018;2018

Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol 1971;32(2):271-5.

Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 1997;23(2):77-85.

Gergi R, Rjeily JA, Sader J, Naaman A. Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography. J Endod 2010; 36(5):904-7.

You SY, Kim HC, Bae KS, Baek SH, Kum KY, Lee W. Shaping ability of Reciprocating motion in curved root canals: a comparative study with micro–computed tomography. J Endod 2011;37(9):1296-1300.

Schäfer E, Diez C, Hoppe W, Tepel J. Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth. J Endod 2002; 28(3):211-6.

Ari H, Erdemir A, Belli S. Evaluation of the effect of endodontic irrigation solutions on the microhardness and the roughness of root canal dentin. J Endod 2004; 30(11):792-5.

Ferrara G, Taschieri S, Corbella S, Ceci C, Del Fabbro M, Machtou P. Comparative evaluation of the shaping ability of two different nickel–titanium rotary files in curved root canals of extracted human molar teeth. J Investig Clin Dent 2017;8(1):e12187.

Bramante CM, Berbert A, Borges RP. A methodology for evaluation of root canal instrumentation. J Endod 1987;13(5):243-5.

Zaia AA, Ferraz CCR, Yoshinari GH, de Souza Filho FJ. A simple method for the analysis of root canal preparation. J Endod 2000;26(3):172-4.

Saber S, Nagy M, Schäfer E. Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single‐file systems in severely curved root canals of extracted teeth. Int Endod J 2015;48(1):109-14.

Hülsmann M, Peters OA, Dummer PM. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Topics 2005;10(1):30-76.

Kataia MM, Roshdy NN, Nagy MM. Comparative analysis of canal transportation using Reciproc blue and wavo one gold in simulated root canals using different kinematics. Future Dent J 2018;4(2):156-9.

Maki K, Ebihara A, Kimura S, Nishijo M, Tokita D, Miyara K, et al. Enhanced root canal-centering ability and reduced screw-in force generation of Reciprocating nickel-titanium instruments with a post-machining thermal treatment. Dent Mater J 2020;39(2):251-5.

Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root fillings. J Endod 2000;26(4):210-6.

Gambarini G, Galli M, Di Nardo D, Seracchiani M, Donfrancesco O, Testarelli L. Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire. J Clin Exp Dent 2019;11(7):e609.

Fangli T, Maki K, Kimura S, Nishijo M, Tokita D, Ebihara A, et al. Assessment of mechanical properties of WaveOne Gold Primary Reciprocating instruments. Dent Mater J 2019;38(3):490-5.

Bürklein S, Flüch S, Schäfer E. Shaping ability of Reciprocating single-file systems in severely curved canals: WaveOne and Reciproc versus WaveOne Gold and Reciproc blue. Odontology 2019;107(1):96-102.

Hoppe CB, Böttcher DE, Justo AM, Só MVR, Grecca FS. Comparison of curved root canals preparation using Reciprocating, continuous and an association of motions. Scanning 2016;38(5):462-8.

Schafer E, Erler M, Dammaschke T. Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth. Int Endod J 2006;39(3):203-12.

Haimed ASA, Abuhaimed TS, Dummer PE, Bryant ST. The root canal shaping ability of WaveOne and Reciproc versus ProTaper Universal and Mtwo rotary NiTi systems. Saudi Endod J 2017;7(1):8-15.