Marker-less patient setup applications of surface-guided radiotherapy and quality assurance: An institutional experience
Keywords:
patient setup, surface-guided radiotherapy, quality assuranceAbstract
Surface-guided radiotherapy (SGRT) has been increasingly implemented in modern radiation therapy practice. It can be utilized for patient positioning and real-time monitoring of organ motion during treatment. Furthermore, the system enables automatic beam interruption when the motion of the target or organ of interest deviates from the planned treatment position. Therefore, quality assurance (QA) of SGRT systems is essential to ensure treatment accuracy and patient safety. SGRT QA can generally be categorized into three levels: daily, monthly, and annual procedures. This article presents our institutional experience in the clinical application of SGRT for patient setup in radiation therapy, as well as the implementation of quality assurance procedures for the SGRT system. The aim is to provide practical guidance for the implementation and further development of SGRT in radiotherapy practice.
References
ทวีป แสงแห่งธรรม. ระบบภาพในงานรังสีรักษา. J Thai Assn of Radiat Oncol. 2016;22:16-23.
ทวีป แสงแห่งธรรม. ระบบภาพในงานรังสีรักษา ใน: ศิวลี สุริยาปี, ทวีป แสงแห่งธรรม, พันทิวา อุณห์ศิริ, บรรณาธิการ ฟิสิกส์ทางรังสีรักษา พิมพ์ครั้งที่ 1. กรุงเทพมหานคร: อิมเมนซ เกรซ; 2563. หน้า 173-188.
Freislederer P, Batista V, Öllers M, Buschmann M, Steiner E, Kügele M, et al. ESTRO-ACROP guideline on surface guided radiation therapy. Radiother Oncol. 2022;173:188-96.
Asada H, Takahashi Y, Ono Y, Kishi N, Matsuo Y, Mizowaki T, et al. Emotional experiences of skin markings among patients undergoing radiotherapy and related factors: a questionnaire-based cross-sectional study. Patient Prefer Adherence. 2022:1359-69.
Oonsiri P, Oonsiri S, Kingkaew S, Vimolnoch M, Kumkhwao J, Duangsuphan P, et al. Patient and staff perspective toward marker‐less patient setup accuracy in breast radiotherapy. J Appl Clin Med Phys. 2026;27:e70452.
Darréon J, Massabeau C, Geffroy C, Maroun P, Simon L. Surface-guided radiotherapy overview: technical aspects and clinical applications. Cancer Radiother. 2023;27:504-10.
Willoughby T, Lehmann J, Bencomo JA, Jani SK, Santanam L, Sethi A, et al. Quality assurance for nonradiographic radiotherapy localization and positioning systems: report of Task Group 147. Med Phys. 2012;39:1728-47.
Bert C, Metheany KG, Doppke K, Chen GT. A phantom evaluation of a stereo‐vision surface imaging system for radiotherapy patient setup. Med Phys. 2005;32:2753-62.
Oonsiri P, Wisetrinthong M, Chitnok M, Saksornchai K, Suriyapee S. An effective patient training for deep inspiration breath hold technique of left-sided breast on computed tomography simulation procedure at King Chulalongkorn Memorial Hospital. Radiat Oncol J. 2019;37:201.
Sauer T-O, Ott OJ, Lahmer G, Fietkau R, Bert C. Prerequisites for the clinical implementation of a markerless SGRT-only workflow for the treatment of breast cancer patients. Strahlenther Onkol. 2023;199:22-9.
Al‐Hallaq HA, Cerviño L, Gutierrez AN, Havnen‐Smith A, Higgins SA, Kügele M, et al. AAPM task group report 302: surface‐guided radiotherapy. Med Phys. 2022;49:e82-e112.
Kutcher GJ, Coia L, Gillin M, Hanson WF, Leibel S, Morton RJ, et al. Comprehensive QA for radiation oncology: report of AAPM radiation therapy committee task group 40. Med Phys. 1994;21:581-618.
Hanley J, Dresser S, Simon W, Flynn R, Klein EE, Letourneau D, et al. AAPM Task Group 198 Report: An implementation guide for TG 142 quality assurance of medical accelerators. Med Phys. 2021;48:e830-e85.
Xiao A, Crosby J, Malin M, Kang H, Washington M, Hasan Y, et al. Single‐institution report of setup margins of voluntary deep‐inspiration breath‐hold (DIBH) whole breast radiotherapy implemented with real‐time surface imaging. J Appl Clin Med Phys.2018;19:205-13.
Pallotta S, Simontacchi G, Marrazzo L, Ceroti M, Paiar F, Biti G, et al. Accuracy of a 3D laser/camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments. Med Phys. 2013;40:011710.
Moser T, Habl G, Uhl M, Schubert K, Sroka-Perez G, Debus J, et al. Clinical evaluation of a laser surface scanning system in 120 patients for improving daily setup accuracy in fractionated radiation therapy. Int J Radiat Oncol Biol Phys. 2013;85:846-53.
เมทินี วิเศษรินทอง และ จารึก ก้านเพ็ชร.การศึกษาปัจจัยที่มีผลต่อระบบภาพพื้นผิวสามมิติแบบตรวจจับตลอดเวลาสำหรับจัดท่าผู้ป่วยฉายรังสี. J Thai Assn of Radiat Oncol. 2024;30:76-90.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Thai Association of Radiation Oncology

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของวารสารมะเร็งวิวัฒน์ ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับ และบุคคลากรท่านอื่น ๆ ใน สมาคมฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใดๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว