Calibration Methods for 192Ir High Dose Rate Brachytherapy Sources
Abstract
The calibration of 192Ir high dose rate source is needed to verify the value certified by the manufacturer before clinical use. Three calibration techniques, in air, in cylindrical phantom and well type chamber were performed to calibrate twelve sources of the 192Ir during March 1999 to August 2003. It was found that almost kerma rates obtained from all calibration systems were less than the manufacturer's by a maximum of 2:35 % except only one measured by in cylindrical phantom method for source number 10 which was 0.38% more. The mean discrepancies were -1.43% ± 0.63 in the range of -0.46% to -2.35% for in air, -0.84 % ± 0.67 in the range of 0.38% to - 2.19% for in phantom, and -1.26% ± 0.42 in the range of -0.73% to -2.07% for well type chamber. The results of all calibration systems agreed within 1.46%. It is not only more reproducibility and simpler set up, but also less time-consuming to use well type chamber for source calibration comparing with the other two techniques. For the institute where only the Farmer chamber is available, the measurements in phantom are easier and quicker to set up than using in air measurement technique.
References
Kutcher GJ, Coia L, Gillin M, et al. Comprehensive QA for Radiation Oncology : Report of AAPM Radiation Therapy Committee Task Group 40. Med Phys 1994; 21: 581-618.
American Association of Physicists in Medicine, Remote Afterloading Technology : A Report of AAPM Task Group No. 41 Remote Afterloading Technology, AAPM Report No 41. New York : the American Institute of Physics, Inc., 1993.
International Atomic Energy Agency. Calibration of Brachytherapy Sources, IAEA-TECDOC-1079. Vienna : International Atomic Energy Agency, 199999.
International Commission on Radiation Units and Measurernents, Dose and Volume Specification for Reporting Interstitial Therapy, ICRU Report 58. Washington DC : International Commission on Radiation Units and Measurements, 1997.
Ezzel G. Evaluation of calibration techniques for the microSelectron. In : Mould RF, ed. Brachytherapy 2, Proceedings Brachytherapy Working Conference, 5 International Selectron Users' Meeting 1988, The Hague, The Netherlands. Leersum, The Netherlands : Nucletron International B.V, 1989 : 61-69.
Venselaar JLM, Brouwer WFM, Van Straaten BHM, Aalbers AHI.. Intercomparison of calibration procedures for Ir-192 HDR Sources in The Netherlands and Belgium, Radiother and Oncol 1994 ; 30 : 155-161.
Baltas D. Quality assurance in brachytherapy with special reference to the microSelectron-HDR. Activity, International Selectron Brachytherapy Journal, Special Report 1993 ; 2: 2-11.
Baltas D, Germani K, Ioannidis GT, et al. Comparison of calibration procedures for " Ir high-dose rate brachytherapy, Int J Radiat Oncol Biol Phys 19999 43 : 653-661.
Khan FH. Brachytherapy. In : The Physics of Radiation Therapy, 2'* ed London : Williams & Wilkins, 1994 : 423.
Hendee WR, Ibbott GF. Sources for implant therapy. In : Radiation Therapy Physics, 2" ed. New York : Mosby, 1996 : 376.
Nair, MTK, Cheng MC. HDR Calibration methods and discrepancies. Int J Radiat Oncol Biol Phys 1997 ; 38: 207-211.
Goetsch SJ, Attix FH, Pearson DW, Thomadsen BR. Calibration of **Ir high-dose-rate afterloading systems. Med Phys 1991 ; 18 : 462-467.
International Atomic Energy Agency. Absorbed Dose Determination in Photon and Electron Beams, Technical Reports Series No. 277. Vienna : International Atomic Energy Agency, 1987.
Krieger H. Messung der Kenndosisleistung punk.t-und linien-formiger HDR-192-imidium Afterloadingstrabler mit einem PMMA-Zylinderphantom, Zeitschrift fur Medizinische Physik 1991 ; 1 : 38-41.
Attix FH. Determination of A,, and Pin in the new AAPM radiotherapy dosimetry protocol. Med Phys 1984 ; 11 : 714-716.
Instruction Manual Afferloading Calibration Phantom Type 9193, for measurements of the nominal air kerma rate of 192-Iridium-HDR afterloading sources with a PMMA cylidrical phantom, PTW-Freiburg, Germany (D402.131.0/1).
Downloads
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของวารสารมะเร็งวิวัฒน์ ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับ และบุคคลากรท่านอื่น ๆ ใน สมาคมฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใดๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว