IsoCal evaluation for isocentric performance check of Varian linacs with C-series and TrueBeam
Keywords:
Linear accelerator, quality assurance, isocenter systemsAbstract
The Varian linear accelerator integrated imaging system has developed patient’s position verification relative to the treatment room. This increases convenient and efficacy during patient setup verification. This system consists of 4 isocenters types: mechanical isocenter, radiation isocenter, kV imaging isocenter, and MV imaging isocenter. The daily quality assurance must take into account the verification of coordinate coincidence. The Isocal verification system is used to evaluate the isocentric performance check of Varian linacs with C-series and TrueBeam. There are Isocal phantom, collimator plate, and software, which is easy to use and produce an accurate result.
References
Balter JM, Antonuk LE. Quality assurance for kilo-and megavoltage in-room imaging and localization for off-and online setup error correction. Int J Radiat Oncol Biol Phys. 2008;71:S48-S52.
Schewe JE, Lam KL, Balter JM, Ten Haken RK. A room‐based diagnostic imaging system for measurement of patient setup. Med Phys. 1998;25:2385-7.
Klein EE, Hanley J, Bayouth J, Yin FF, Simon W, Dresser S, et al. Task Group 142 report: Quality assurance of medical accelerators a. Med Phys. 2009;36:4197-212.
Bissonnette JP, Balter PA, Dong L, Langen KM, Lovelock DM, Miften M, et al. Quality assurance for image‐guided radiation therapy utilizing CT‐based technologies: a report of the AAPM TG‐179. Med Phys. 2012;39:1946-63.
Moragues-Femenia S, Calvo-Ortega J, Pozo-Massó M, Casals-Farran J. EP-1781: Dosimetric impact of CBCT isocenter misaligment on target dose coverage in cranial SRS. Radiother Oncol. 2016;119:S835.
Lutz W, Winston KR, Maleki N. A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys. 1988;14:373-81.
Du W, Gao S, Jiang W, Kudchadker RJ. Independent evaluation of the effectiveness of IsoCal in improving image center accuracy on Varian TrueBeam and Clinac machines. J Appl Clin Med Phys. 2018;19:483-90.
Rowshanfarzad P, Sabet M, O'connor DJ, Greer PB. Isocenter verification for linac‐based stereotactic radiation therapy: review of principles and techniques. J Appl Clin Med Phys. 2011;12:185-95.
Bissonnette J-P, Moseley D, White E, Sharpe M, Purdie T, Jaffray DA. Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy. Int J Radiat Oncol Biol Phys. 2008;71:S57-S61.
พันทิวา อุหณ์ศิริ. การประกันคุณภาพเครื่องฉายรังสีรุ่น TrueBEAM ด้วยวิธี Machine Performance Check (MPC). J Thai Assoc Radiat Oncol. 2018;24:45-52.
Gao S, Du W, Balter P, Munro P, Jeung A. Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on‐board imager and electronic portal imaging device imaging systems. J Appl Clin Med Phys. 2014;15:164-81.
Downloads
Published
How to Cite
Issue
Section
License
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของวารสารมะเร็งวิวัฒน์
ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับ และบุคคลากรท่านอื่น ๆ ใน สมาคมฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใดๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว