Surface dose measurements in clinical 6 MeV-X-photon beams : Comparison of Measurements and MC calculations

Authors

  • J. M. Jensen CancerCare Manitoba, Winnipeg, Canada
  • G. Asuni CancerCare Manitoba, Winnipeg, Canada
  • I. Lütjens Klinik f. Strahlentherapie, UK SH, Campus Kiel, Germany

Abstract

For radiotherapy of superfi cial lesions, but also in intensity modulated radiotherapy (IMRT), 6 MeV-X-photon beams are preferred, with relative surface doses, dependent on fi eld size and SSD, of 8 % to 28 %. Depending on absorption material within the beam this values can vary considerable. The infl uence of a block tray, different metals and a new type of transmission detector on surface doses as well as on other beam parameters have been investigated. The surface doses as well as some other fi eld parameters have been checked by means of a plane parallel ionization chamber (Markus chamber, type 23 343, PTW-Freiburg, Germany). Because of specifi c design features the readings have to be corrected, and the results have been verifi ed by Monte Carlo (MC) simulations and calculations: Measurements agreed well with calculations within Δ ≈ 3 %. So it could be shown for the used Markus chamber, type 23 343, that the applied correction function is suitable for open fi elds as well as for blocked fi elds at different clinical used SSDs.

References

B. J. Gerbi, F. M. Khan: Measurement of dose in the buildup region using fi xed-separation plane-parallel ionization chambers. Med. Phys. 17, 17-26 (1990)

S. Kim, C. R. Liu, et al : Photon beam skin dose analysis for different clinical setups. Med. Phys. 25, 860-866 (1998)

D. E. Mellenberg: Determination of build-up region over-response corrections for a Markus-type chamber. Med. Phys. 17, 1041-1044 (1990)

W. Abdel-Rahman, J. P. Seuntjens, et al : Validation of Monte Carlo calculated surface doses for megavoltage photon beams. Med. Phys. 32, 286-98 (2005)

CRC Handbook of Chemistry and Physics (Ed. D. R. Lide) , CRC Press, Boca Raton 2000

IBA Information-brochure for "COMPASS", Schwarzenbruck, Germany, 2007

S. Venkataraman, K. Malkoske, M. Jensen, et al : The infl uence of a novel transmission detector on 6 MV x-ray beam characteristics. Phys. Med. Biol. 54, 3171-83 (2009)

PTW-Freiburg, Detector-catalog, Freiburg, Germany, 2007

DIN 6800-2: Dosimetrie hochenergetischer Photonen- und Elektronenstrahlung mit Ionisationskammern. Beuth Verlag Berlin, 2008

H. Reich (Hrg.) : Dosimetrie ionisierender Strahlung. B. G. Teubner, Stuttgart 1990

J. M. Jensen, G. Asuni, I. Lütjens, B. McCurdy : Oberfl ächendosisbestimmung in klinischen 6 MeV X-Photonenfeldern. mt-medizintechnik 129, 144-147 (2009)

R. G. Jaeger, W. Hübner (Eds.): Dosimetrie und Strahlenschutz. G. Thieme Verlag, Stuttgart 1974

Downloads

Published

2010-06-29

How to Cite

1.
Jensen JM, Asuni G, Lütjens I. Surface dose measurements in clinical 6 MeV-X-photon beams : Comparison of Measurements and MC calculations. J Thai Assn of Radiat Oncol [Internet]. 2010 Jun. 29 [cited 2024 Dec. 21];16(1):15-9. Available from: https://he01.tci-thaijo.org/index.php/jtaro/article/view/203511

Issue

Section

Original articles