Imaging in radiotherapy
References
Murphy MJ, Balter J, Balter S, BenComo JA Jr, Das IJ, Jiang SB, et al. “The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75”. Med Phys. 2007; 34: 4041-63.
Coia LR, Schutheiss TE, Hanks GE, et al. “A practical guide to CT simulation”. Madison, WI: Advanced Medical Publishing, 1995.
Chen L1, Price RA Jr, Wang L, Li J, Qin L, McNeeley S, et al. “MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT”. Int J Rad Oncl Biol Phys. 2004; 60: 636-47.
Dawson LA, Sharpe MB. “Image-guided radiotherapy: rational, benefit, and limitations”. Lancet Oncol. 2006; 7: 848-58.
Foulkes KM, Ostwald PM, Kron T. “A clinical comparison of different film systems for radiotherapy portal imaging”. Med Dosim. 2001; 26: 281-4.
Herman MG, Kruse JJ, Hagness CR. “Guide to clinical use of electronic portal imaging”. J App Clin Med Phys. 2000; 1: 38-57.
Yin FF, Wong J, Balter J, et al. “The role of in-room kV X-ray imaging for patient setup and target localization”. AAPM Report No. 104. Collage Park, ND: AAPM; 2009.
Sorcini B, Tilikidis. “A clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform)”. Cancer Radiotherapy, 2006; 10: 252-7.
Ma CM, Paskalev K. “In-room CT techniques for image-guided radiation therapy”. Med Dosim. 2006; 31: 30-9.
Broderick M, Menezes G, Leech M, Coffey M, Appleyard RM . “A comparison of kilovoltage and megavoltage cone beam CT in radiotherapy”. J of Radiother in pract. 2007; 6:173-8.
Gurjar OP, Mishra SP, Bhandari V, Pathak P, Pant S, Patel P. “A study on the necessity of kV-CBCT imaging compared to kV-orthogonal portal imaging based on setup errors: considering other socioeconomical factors”. J Cancer Res Ther. 2014; 10: 583-6.
van der Meer S, Bloemen-van Gurp E, Hermans J, Voncken R, Heuvelmans D, Gubbels C, et al. Critical assessment of intramodality 3D ultrasound imaging for prostate IGRT compared to fiducial markers”. Med Phys. 2013;40:071707.
Willoughby T, Lehmann J, Bencomo JA, Jani SK, Santanam L, Sethi A, et al. “Quality assurance for nonradiographic radiotherapy localization and positioning systems: Report of Task Group 147”. Med Phys. 2012; 39: 1728-47.
Li G, Ballangrud A, Chan M, Ma R, Beal K, Yamada Y, et al. “Clinical experience with two frameless stereotactic radiosurgery (fSRS) systems using optical surface imaging for motion monitoring”. J Appl Clin Med Phys. 2015;16:5416.
Latty D, Stuart KE, Wang W, Ahern V. “Review of deep inspiration breath-hold techniques for the treatment of breast cancer”. J Med Radiat Sci. 2015; 62: 74-81.
Mayyas E, Chetty IJ, Chetvertkov M, Wen N, Neicu T, Nurushev T, et al. “Evaluation of multiple imagebased modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: A prospective study”. Med Phys. 2013; 40; 41707_1-9.
Jaffray D, Mutic S, Fallone B, Raaymakers B. “MRI-guided radiation therapy”. Med Phys. 2013; 40: 390.
Coia LR, Schutheiss TE, Hanks GE, et al. “A practical guide to CT simulation”. Madison, WI: Advanced Medical Publishing, 1995.
Chen L1, Price RA Jr, Wang L, Li J, Qin L, McNeeley S, et al. “MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT”. Int J Rad Oncl Biol Phys. 2004; 60: 636-47.
Dawson LA, Sharpe MB. “Image-guided radiotherapy: rational, benefit, and limitations”. Lancet Oncol. 2006; 7: 848-58.
Foulkes KM, Ostwald PM, Kron T. “A clinical comparison of different film systems for radiotherapy portal imaging”. Med Dosim. 2001; 26: 281-4.
Herman MG, Kruse JJ, Hagness CR. “Guide to clinical use of electronic portal imaging”. J App Clin Med Phys. 2000; 1: 38-57.
Yin FF, Wong J, Balter J, et al. “The role of in-room kV X-ray imaging for patient setup and target localization”. AAPM Report No. 104. Collage Park, ND: AAPM; 2009.
Sorcini B, Tilikidis. “A clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform)”. Cancer Radiotherapy, 2006; 10: 252-7.
Ma CM, Paskalev K. “In-room CT techniques for image-guided radiation therapy”. Med Dosim. 2006; 31: 30-9.
Broderick M, Menezes G, Leech M, Coffey M, Appleyard RM . “A comparison of kilovoltage and megavoltage cone beam CT in radiotherapy”. J of Radiother in pract. 2007; 6:173-8.
Gurjar OP, Mishra SP, Bhandari V, Pathak P, Pant S, Patel P. “A study on the necessity of kV-CBCT imaging compared to kV-orthogonal portal imaging based on setup errors: considering other socioeconomical factors”. J Cancer Res Ther. 2014; 10: 583-6.
van der Meer S, Bloemen-van Gurp E, Hermans J, Voncken R, Heuvelmans D, Gubbels C, et al. Critical assessment of intramodality 3D ultrasound imaging for prostate IGRT compared to fiducial markers”. Med Phys. 2013;40:071707.
Willoughby T, Lehmann J, Bencomo JA, Jani SK, Santanam L, Sethi A, et al. “Quality assurance for nonradiographic radiotherapy localization and positioning systems: Report of Task Group 147”. Med Phys. 2012; 39: 1728-47.
Li G, Ballangrud A, Chan M, Ma R, Beal K, Yamada Y, et al. “Clinical experience with two frameless stereotactic radiosurgery (fSRS) systems using optical surface imaging for motion monitoring”. J Appl Clin Med Phys. 2015;16:5416.
Latty D, Stuart KE, Wang W, Ahern V. “Review of deep inspiration breath-hold techniques for the treatment of breast cancer”. J Med Radiat Sci. 2015; 62: 74-81.
Mayyas E, Chetty IJ, Chetvertkov M, Wen N, Neicu T, Nurushev T, et al. “Evaluation of multiple imagebased modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: A prospective study”. Med Phys. 2013; 40; 41707_1-9.
Jaffray D, Mutic S, Fallone B, Raaymakers B. “MRI-guided radiation therapy”. Med Phys. 2013; 40: 390.
Downloads
Published
2016-06-30
How to Cite
1.
แสงแห่งธรรม ท. Imaging in radiotherapy. J Thai Assn of Radiat Oncol [Internet]. 2016 Jun. 30 [cited 2024 Dec. 21];22(1):16-23. Available from: https://he01.tci-thaijo.org/index.php/jtaro/article/view/203076
Issue
Section
Original articles
License
บทความที่ได้รับการตีพิมพ์เป็นลิขสิทธิ์ของวารสารมะเร็งวิวัฒน์
ข้อความที่ปรากฏในบทความแต่ละเรื่องในวารสารวิชาการเล่มนี้เป็นความคิดเห็นส่วนตัวของผู้เขียนแต่ละท่านไม่เกี่ยวข้องกับ และบุคคลากรท่านอื่น ๆ ใน สมาคมฯ แต่อย่างใด ความรับผิดชอบองค์ประกอบทั้งหมดของบทความแต่ละเรื่องเป็นของผู้เขียนแต่ละท่าน หากมีความผิดพลาดใดๆ ผู้เขียนแต่ละท่านจะรับผิดชอบบทความของตนเองแต่ผู้เดียว