การประกันคุณภาพเครื่องฉายรังสีรุ่น TrueBEAM ด้วยวิธี Machine Performance Check (MPC)

Authors

  • พันทิวา อุณห์ศิริ ฝ่ายรังสีวิทยา โรงพยาบาลจุฬาลงกรณ์ สภากาชาดไทย

References

TrueBEAM [On line] [cited 2017 November 23], Available from: https://www.varian.com/oncology/products/treatment-delivery/truebeam-radiotherapy-system

Chang Z, Wu Q, Adamson J, Ren L, Bowsher J, Yan H, et al. Commissioning and dosimetric characteristic of TrueBEAM system: Composite data of three TrueBEAM machines. Med. Phy. 2012; 39: 6981-7019

Klein EE, Hanley J, Bayouth J, Yin F-F, Simon W, Dresser S, et al. Task Group 142 report: quality assurance of medical accelerator. Med. Phy. 2009; 36: 4197-212.

International Electrotechnical Commission Publication 976. Medical electron accelerator-functional performance characteristics.1989.

International Electrotechnical Commission Publication 977. Medical electron accelerators in the range 1 MeV-50 MeV- guideline for functional performance characteristics. 1989.

Clivio A, Vanetti E, Rose S, Nicolini G, Belosi M, Cozzi L, et al. Evaluation of the Machine Performance Check application for TrueBEAM Linac. Radiation Oncology. 2015; 10: 97.

Kutcher GJ, Coia L, Gillin M, Hanson WF, Leibel S, Morton RJ, et al. Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. Med Phys. 1994; 21: 581-618.

Bissonette JP, Balter P, Dong L, Langen KM, Lovelock DM, Miften M, et al. Quality assurance for imageguided radiation therapy utilizing CT-based technologies: report the AAPM TG-179. Med Phys. 2012; 39: 1946-63.

Isocentric Beam Checker [On line][cited 2017 October 31], Available from: https://www.rpdinc.com/isocentric-beam-checker-1-3866.html

PTW QUICK CHECK [On line][cited 2017 October 31], Available from: http://www.medsuro.nl/radiotherapie/linac-qa

Gao S, Du W, Balter P, Munro P, Jeung A. Evaluation of IsoCal geometric calibration system for Varian Linac equipped with on-board imager and electronic portal imaging device imaging system. J Appl Clin Med Phys. 2014; 15: 164-81.

Barnes M and Greer P. Evaluation of the truebeam machine performance check (MPC) geometric checks for daily IGRT geometric accuracy quality assurance. J Appl Clin Med Phys. 2017; 18: 200-206.

Greer P and Barnes M. Evaluation of the truebeam machine performance check (MPC) beam constancy checks for flattened and flattening filter- free (FFF) photon beams. J Appl Clin Med Phys. 2017; 18: 139-150.