Accuracy and Outcomes of Freehand Thoracic Pedicle Screw Placement using Qi’s Technique
DOI:
https://doi.org/10.31584/jhsmr.2022868Keywords:
accuracy, freehand, pedicle screw, thoracic spineAbstract
Objective: Many authors have proposed a variety of strategies for freehand thoracic pedicle screw (PS) placement based on identifying ideal entry points and trajectories in the transverse and sagittal planes. This study aimed to assess the accuracy and safety of using a landmark proposed by Qi et al., for determining the entry point and trajectory for freehand thoracic PS placement.
Material and Methods: A total of 59 consecutive adult patients who underwent thoracic (T1-T12) PS fixation using Qi’s landmark were enrolled in this retrospective study. Demographic and diagnostic information, adverse events, and postoperative pedicle violation grading were all recorded for analysis.
Results: A total of 398 thoracic pedicle screw insertions were analyzed. There were no cases of postoperative neurological deterioration, however two patients required revision surgery to remove a misplaced screws at T6 and T7 due to significant medial wall violation. A total of 360 PSs (90.5%) and 28 PSs (7.0%) were categorized as having high accuracy and low accuracy, respectively. The remaining 10 PSs (2.5%) in the lateral cortex violation group were considered clinically acceptable due to their position in the rib-pedicle unit. The most common location for misplaced screws was the T4 to T8 vertebral region.
Conclusion: In terms of accuracy and safety, our findings support using Qi’s technique for freehand thoracic PS placement. The rate of screw misplacement was comparable to that of other techniques. Surgeons should be familiar with the unique anatomy of the mid-thoracic region because it constitutes the most common site of misplaced screws.
References
Mattei TA, Meneses MS, Milano JB, Ramina R. “Free-hand” technique for thoracolumbar pedicle screw instrumentation: critical appraisal of current “state-of-art”. Neurol India 2009;57:715-21.
Erkan S, Hsu B, Wu C, Mehbod AA, Perl J, Transfeldt EE. Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines? Eur Spine J 2010;19:71-7.
Malhotra D, Kalb S, Rodriguez-Martinez N, Hem DD, Perez-Orribo L, Crawford NR, et al. Instrumentation of the posterior thoracolumbar spine: from wires to pedicle screws. Neurosurgery 2014;10:497-504.
Puvanesarajah V, Liauw JA, Lo SF, Lina IA, Witham TF. Techniques and accuracy of thoracolumbar pedicle screw placement. World J Orthop 2014;5:112-23.
Weinstein JN, Rydevik BL, Rauschning W. Anatomic and technical considerations of pedicle screw fixation. Clin Orthop Relat Res 1992;284:34-46.
Elmi-Terander A, Burstrom G, Nachabe R, Skulason H, Pedersen K, Fagerlund M, et al. Pedicle Screw Placement Using Augmented Reality Surgical Navigation With Intraoperative 3D Imaging: A First In-Human Prospective Cohort Study. Spine (Phila Pa 1976) 2019;44:517-25.
Rienmuller A, Buchmann N, Kirschke JS, Meyer EL, Gempt J, Lehmberg J, et al. Accuracy of CT-navigated pedicle screw positioning in the cervical and upper thoracic region with and without prior anterior surgery and ventral plating. Bone Joint J 2017;99:1373-80.
Gokcen HB, Erdogan S, Ozturk S, Gumussuyu G, Bayram I, Ozturk C. Sagittal orientation and uniform entry for thoracic pedicle screw placement with free-hand technique: A retrospective study on 382 pedicle screws. Int J Surg 2018;51:83-8.
Steinmetz MP, Rajpal S, Trost G. Segmental spinal instrumentation in the management of scoliosis. Neurosurgery 2008;63:131-8.
Lien SB, Liou NH, Wu SS. Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine. Eur Spine J 2007;16:1215-22.
Balestrino A, Gondar R, Jannelli G, Zona G, Tessitore E. Surgical challenges in posterior cervicothoracic junction instrumentation. Neurosurg Rev 2021;44:3447-58.
Gang C, Haibo L, Fancai L, Weishan C, Qixin C. Learning curve of thoracic pedicle screw placement using the freehand technique in scoliosis: how many screws needed for an apprentice? Eur Spine J 2012;21:1151-6.
Qi DB, Wang JM, Zhang YG, Zheng GQ, Zhang XS, Wang Y. Positioning thoracic pedicle screw entry point using a new landmark: a study based on 3-dimensional computed tomographic scan. Spine (Phila Pa 1976) 2014;39:e980-8.
Human anatomy atlas (version 2021.0) [homepage on the Internet]. Massachusetts: Argosy Publishing, Inc.; 2007-2020 [cited 2021 Jan 17]. Available from: www.visiblebody.com
Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 1990;15:11-4.
Cho SK, Skovrlj B, Lu Y, Caridi JM, Lenke LG. The effect of increasing pedicle screw size on thoracic spinal canal dimensions: an anatomic study. Spine (Phila Pa 1976) 2014;39:e1195-200.
Husted DS, Yue JJ, Fairchild TA, Haims AH. An extrapedicular approach to the placement of screws in the thoracic spine: an anatomic and radiographic assessment. Spine (Phila Pa 1976) 2003;28:2324-30.
Kim JH, Choi GM, Chang IB, Ahn SK, Song JH, Choi HC. Pedicular and extrapedicular morphometric analysis in the Korean population: computed tomographic assessment relevance to pedicle and extrapedicle screw fixation in the thoracic spine. J Korean Neurosurg Soc 2009;46:181-8.
Cui XG, Cai JF, Sun JM, Jiang ZS. Morphology study of thoracic transverse processes and its significance in pedicle-rib unit screw fixation. J Spinal Disord Tech 2015;28:e74-7.
Kim YJ, Lenke LG. Thoracic pedicle screw placement: freehand technique. Neurol India 2005;53:512-9.
Modi H, Suh SW, Song HR, Yang JH. Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand technique. Int Orthop 2009;33:469-75.
Kilicaslan OF, Tokgoz MA, Butun S, Nabi V, Akalin S. Accuracy of Freehand Versus Modified Funnel Technique for Pedicle Screw Insertion in the Thoracic Spine. Turk Neurosurg 2021;31:795-802.
Avila MJ, Baaj AA. Freehand Thoracic Pedicle Screw Placement: Review of Existing Strategies and a Step-by-Step Guide Using Uniform Landmarks for All Levels. Cureus 2016;8:e501.
Swaminathan G, Muralidharan V, Devakumar D, Joseph BV. Accuracy of the freehand (fennell) technique using a uniform entry point and sagittal trajectory for insertion of thoracic pedicle screws: A computed tomography-based virtual simulation study. Neurol India 2020;68:468-71.
Zhang ZF. Freehand Pedicle Screw Placement Using a Universal Entry Point and Sagittal and Axial Trajectory for All Subaxial Cervical, Thoracic and Lumbosacral Spines. Orthop Surg 2020;12:141-52.
Karapinar L, Erel N, Ozturk H, Altay T, Kaya A. Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? J Spinal Disord Tech 2008;21:63-7.
Pan Y, Lu GH, Kuang L, Wang B. Accuracy of thoracic pedicle screw placement in adolescent patients with severe spinal deformities: a retrospective study comparing drill guide template with free-hand technique. Eur Spine J 2018;27:319-26.
Perna F, Borghi R, Pilla F, Stefanini N, Mazzotti A, Chehrassan M. Pedicle screw insertion techniques: an update and review of the literature. Musculoskelet Surg 2016;100:165-9.
Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, et al. Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment. J Bone Joint Surg Am 1995;77:1200-6.
Chung KJ, Suh SW, Desai S, Song HR. Ideal entry point for the thoracic pedicle screw during the free hand technique. Int Orthop 2008;32:657-62.
Downloads
Published
How to Cite
Issue
Section
License